3.
Delay
A variable delay control is available for the LS/RS pair and can be varied by upto 40ms
in 1ms steps.
To change the delay press the “Delay” button and use the rotary controller to alter the delay.
4.
Low Pass Filter
A low pass filter is provided with a cut-off frequency ranging from 20KHz to50Hz.
To change the cut off frequency press the “LPF” button and use the rotary controller to alter the
frequency.
5.
High Pass Filter
A high pass filter is provided with a cut-off frequency ranging from 20Hz to 200Hz.
To change the cut off frequency press the “HPF” button and use the rotary controller to alter the