Owner's manual
IMPORTANT INFORMATION:
Warning devices are strictly regulated and governed by Federal, State and Municipal ordinances. These devices shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.
To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at www.soundoffsignal.com/sales-support.
If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800338.7337 (press #4 to skip the automated message).
Questions or comments that do not require immediate attention may be emailed to techservices@soundoffsigal.com.
SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
nFORCE™ LED Lightbar
nForce Lightbar 05.14
ELECTRICAL INSTALLATION (CONTINUED)
Warning Flash Pattern Configuration:
a. Apply voltage to Ignition Input Wire and then set Switch #2 on Breakout box to down position (Switch #1 must be in Up position)
b. Apply voltage to the activation wire of the function which requires pattern to be changed (i.e. Front Corner, Takedown, Left Alley, etc.)
c. Apply voltage to the Mode activation wire to configure mode 2 flash patterns, leave Mode activation wire floating to configure mode 1 flash patterns
d. Momentarily apply voltage to the pattern select wire to change the warning flash pattern
e. Set Switch #2 on Breakout box to up position to save settings and return light-bar to normal operating mode
NOTE: Takedown and Alley light patterns are limited to pattern #1 – 11
7.
*fpm=Flashes per Minute
**fps=Flashes per Second
FLASH PATTERNS
# Name
SAE
Compliant
Timing
Color Sequence fpm fps
1 Random Single #1
Yes
#1
Variable - -
2 Random Single #2
No
#1
Variable - -
3 Quint
Yes
#1
Alternating 70 1.2
4 Quad 2
Yes
#1
Variable - -
5 Q-Switch
Yes
#1
Variable - -
6 Double
Yes
#1
Alternating 115 1.9
7 Power Pulse
Yes
#1
Alternating 180 3.0
8 RoadRunner
Yes
#1
Alternating 115 1.9
9 SlowRunner
Yes
#1
Alternating 70 1.2
10 Warp
No
#1
Alternating 350 5.8
11 Inter-cycle
No
#1
Alternating - -
12 Warp 1, 2, 3
No
#1
Variable - -
13 E-Single
Yes
#1
Alternating 125 2.1
14 E-Double
Yes
#1
Alternating 125 2.1
15 E-Triple
Yes
#1
Alternating 125 2.1
16 Random Dual #1
Yes
#1/2
Variable - -
17 Random Dual #2
No
#1/2
Variable - -
18 Quint Dual
Yes
#1/2
Alternating 70 1.2
19 Quad 2 Dual
Yes
#1/2
Variable - -
20 Q-Switch Dual
No
#1/2
Variable - -
21 Double Dual
Yes
#1/2
Alternating 115 1.9
22 Power Pulse
Yes
#1/2
Alternating 180 3.0
23 RoadRunner Dual
Yes
#1/2
Alternating 115 1.9
24 SlowRunner Dual
Yes
#1/2
Alternating 70 1.2
25 Warp Dual
No #1/2 Alternating 350 5.8
26 Inter-cycle Dual
No #1/2 Alternating - -
27 Warp 1, 2, 3, Dual
No #1/2 Variable - -
28 Dual Color Flash 1
No #1/2 Variable - -
29 Dual Color Flash 2
No #1/2 Variable - -
30 Impact
No #1/2 Variable - -
31 Explosion
No #1/2 Variable - -
32 Tri Color Flash 1
No #1/2/3 Alternating - -
ARROW PATTERNS
# Name
SAE
Compliant
Timing
Color Sequence fpm fps
1 Single Fast
No - - - -
2 Single Slow
No - - - -
3 Chaser Fast
No - - - -
4 Chaser Slow
No - - - -
5 Fill Fast
No - - - -
6 Fill Slow
No - - - -