User Manual
Table Of Contents
2. POWER ON LED: When the unit is on it is lit.
1 32 4 5 6
7
3. LINK OUT / Termination switch: When unpressed, LINK OUT is available to route
DMX data from DMX Input. When pressed it terminates DMX Link Output and it
can’t be used to get DMX data.
4. DMX Line Output: It routes all DMX data from DMX Input connector. It can be
terminated by pressing switch n.3.
5. DMX Input: This connector receive DMX data from lighting consoles, xtures or
other DMX512 standard equipment.
6. ON/OFF Switch: It switches On and Off the unit.
7. MAINS Connector with FUSE Holder: Connect here mains cable (included). This
connector contains a security Fuse. To prevent the risk of re and damaging the
unit, please use only of the recommended fuse type as described in the specica-
tions table. Before replacing the fuse, make sure the unit turned off and discon-
nected from the AC outlet.
3. MAINS CONNECTIONS
Connect the device to the mains with the power-plug. The wire correspondence is as
follow:
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Earth
The earth must to be connected! Pay attention to the safety! Before taking
into operation for the rst time, the installation has to be approved by an