User Manual

NOTE: Please note only one unit must be set as a master. The slave units Will
Follow the controls from the master unit. The foot pedal can be connected to
the master unit To control all connected units.
Using a DMX controller
Each unit uses 15 DMX channels. To control all units the same, DMX value must be set
the same on all units (e.g.: all to A001).
To control units individually each unit must have its own DMX start address and each
address must be at least 15 channels apart. No DMX address values must cross (Ex-
ample unit 1 set to A001, unit 2 set to A016 etc., each 15 channels apart).
Using ob-3 mode
This is designed to use a basic 3-channel DMX controller and will only give control of
the RGB of all par cans. Individual control of each can is not available nor are any of the
built in programs.
To select ob-3 mode:
f Press the MENU button until ob-3 is displayed.
f Press ENTER to conrm
11. TROUBLE SHOOTING
Problems Check LIst Troubleshooting
No Output. The Prod-
uct does not work
Check if the power cord is
connect in input mains socket
of the party Bar.
Check if the ambient tempera-
ture in a safe range
Make sure there is mains
present to cable. Check the
fuse or replace the cable
After temperature is suit-
able, protect function will
cancel automatically
LED Dimmed
Check if power cord is connect
in the input mains socket of
the 4LEDKIT-PARTY
Make sure mains input volt-
age is the correct voltage
No DMX input
Check if cable is damaged or
connections pin polarity is
correct
Check if DMX mode is set
properly
Check if there are 2 units set as
master in the whole circuit
Correct DMX polarity or
change the cable.
Set up function mode as
DMX
Set 1 unit in Slave Mode
13
ENGLISH
4LEDKIT-PARTY User manual