User manual
Source Technologies, LLC ST9630 Secure MICR Printer User’s Guide  
52
This command identifies the data to be printed in the first column of the report. It is a 
maximum of 14 characters in length. If less than 14 characters are sent, the printer fills 
the field with spaces when the audit report is printed. This field is only recorded in the 
audit report; it is not printed on the check. 
Audit Report Field Two-MICR Line &%SMDd..d$ or &%SM7d..d$ 
&%SMD or &%SM7      Lead in sequence 
d..d      Data to be printed 
$      Command terminator 
This command identifies the data to be printed in the second column of the report. It is a 
maximum of 40 characters in length. 
Audit Report Field Three  &%SQ3d..d$ 
&%SQ3  Lead in sequence  
d..d  Data to be printed 
$  Command terminator 
This command identifies the data to be printed in the third column of the report. It is a 
maximum of 40 characters. 
Audit Report Field Four  &%SQ4d..d~ 
&%SQ4  Lead in sequence 
d..d  Data to be printed 
~  Command terminator 
This command identifies the data to be printed in the fourth column of the report. It is a 
maximum of 16 characters in length. Since a total of this field can be provided at the end 
of the Audit Trail Report it is typically used for the convenience amount field. 
Note: This is the only command where the $ is not a command terminator. The 
tilde ~ (hex 7E) acts as the command terminator. 
Audit Report Field Five  &%SQ5d..d$ 
&%SQ5  Lead in sequence 
d..d  Data to be printed 
$  Command terminator 
This command identifies the data to be printed in the fifth column of the report. This field 
is a maximum of eight characters. 
Audit Report Field Six  &%SQ6d..d$ 
&%SQ6  Lead in string 
Audit Trail Reports | 8 