User manual
Source Technologies, LLC ST9630 Secure MICR Printer User’s Guide  
53
d..d  Data to be printed 
$  Command terminator 
This command identifies the data to be printed in the sixth column of the report. This 
field is a maximum of 19 characters. 
Audit Report Field Seven  &%SQ7d..d$ 
&SQ&7  Lead in string 
d..d  Data to be stored 
$  Command terminator 
This command identifies the data to be printed in the seventh column of the report. This 
field is a maximum of 12 characters. The data in this field is recorded for the Audit 
Report only. 
Print and Purge Audit Report  &%SPURGExx$ 
&%SPURGE  Lead in string 
x  option(s) 
$  Command terminator 
This command prints and purges the Audit Report. All recorded information is deleted. 
The optional field can be any combination of the following letters: 
T  Total Field 4 
O  Overlay 
S  Sort by MICR line 
  C  Communicate - send report to host instead of printing - see additional 
    information below on SPRINT command 
For example, the command &%SPURGES$ sorts the records by the MICR line while the 
command &%SPURGESO$ sorts the records by the MICR line and prints an overlay 
with the data. 
Options can be forced on with these commands but they cannot be forced off. In other 
words, if the front panel overlay setting is on, it cannot be forced off by a datastream 
command. If the front panel overlay setting is off, however, a datastream command can 
activate this feature. This command can only be accessed with a valid password 
command. 
Print Audit Report  &%SPRINTxx$ 
&%SPRINT  Lead in string 
x  option(s) 
$  Command terminator 
Prints the Audit Report 
Audit Trail Reports | 8 