Datasheet

21
CLIPPER
INSTRUCTIONS
Instruction For Assembly
Insertion and extraction of contacts
Single wires
Contact insertion and extraction is performed without a tool thanks to te retainer plate system.
Special case of jacketed cables
1) Locate the first contact and the corresponding cavity.
2) The wire should described a buckle as describe below.
3) Unlock the retainer plate as described above.
4) Fully insert the wired contact in the cavity.
5) Respect the same procedure for the other contacts
6) Once again squeeze the retainer plate flaps and push
forwards : the plate is then locked
Special case of jacketed cables
7) Manually fully screw the adaptor and the backshell
on the connector.
Caution : In the sealed version don’t forget the O-ring.
8) Push forwards the cable of 10 mm in the backshell.
9) Fully screw on the backshell with a wrench while
keeping the adaptor with another wrench.
Note : The plate can only be pushed back if the
contacts are correctly engaged (backup- security)
Insertion
1) With the thumb and index finger,
squeeze the retainer plate flaps and
pull backwards : the plate is then in
the unlocked position.
2) Fully insert the wired contact in the
cavity.
3) Repeat the same procedure for the
other contacts.
4) Once again squeeze the retainer plate
flaps and push forwards: the plate is
then locked and retains the contacts
(90 N of retention force for contacts of
1.6 mm dia.)
5) The plate can only be pushed backed
if the contacts are correctly engaged
(backup security)
Extraction
1) With the thumb and index finger,
squeeze the retainer plate flaps and
pull backwards : the plate is then in
the unlocked position.
2) Pull the contact wire: the the contact
comes out of the cavity.
3) Repeat the same procedure for the
other contacts.