Datasheet

19
CLIPPER
INSTRUCTIONS
Panel mounting
There are two types of mounting possible: through the
front or through the back of the panel.
Panel cut-out
• For a sealed mounting, the seal gasket shall be used,
making sure the surface is in good condition.
• Observe the drilling hole diameters indicated below.
• Use the recommended screws :
M3 (all shells)
or # 4.40 (shells 1 and 2)
# 6.32 (shells 3 and 4)
• Respect the coupling torques indicated M3
(all shells) : 0.70 N.m MAX
Ø H
J
J
4 holes ØG
Tailles
de
H
J
G
1
0.85
0.84
0.13
2
0.98
0.97
0.13
3
1.22
1.13
0.15
4
1.61
1.44
0.15
Shell
sizes
Dim.
(inches)
Front Mounting Rear Mounting
.157 max
.157 max
.157" max
(4 mm max)
.157" max
(4 mm max)