Datasheet
Clipper Industrial Plastic Connectors
• Squeeze the plier handles until a final click sounds, release, the pliers should
open by themselves.
• Fully insert the contact into the locator (corresponding gauge), the contact
crimping lugs should be directed upwards, according to the drawing.
• Put the stripped wire in the crimping part until it comes in contact with the
stopper plate. Make sure that no strands stick out of the crimping part.
• Squeeze the plier handles until a final click sounds, release, the pliers should
open by themselves.
• Check the overall aspect of the crimping.
• Push the cable into the contact barrel and make sure the cable strands stick out
of the inspection hole.
• The pliers must be used on the jaws side.
• Squeeze the plier handles until a final click sounds, release, the pliers should
open by themselves.
• Insert both wire and contact (or wire, reducing sleeve and contact) between the
4 jaws until stopped by the locator.
• Fully squeeze until a final click sounds, the pliers should open once the crimping
is performed
• Extract the wire and crimped contact, then check the overall aspect of the
crimping.
Stamped and Formed Contacts
(#16 and #20)
Y16SCMCL3
Machined Crimping Contacts
(#16 and #20)
8365
with
locator
8365-02
Manual Crimping Tool
18