Panel mounting
There are two types of mounting possible: through the front or through
the back of the panel.
Panel cut-out
• For a sealed mounting, the seal gasket shall be used, making sure the
surface is in good condition.
• Observe the drilling hole diameters indicated below.
• Use the recommended screws :
M3 (all shells)
or # 4.40 (shells 1 and 2)
# 6.32 (shells 3 and 4)
• Respect the coupling torques indicated M3
(all shells) : 0.70 N.m Max
Rear Mounting
.157" max
(4 mm max)
Front Mounting
.157" max
(4 mm max)
Panel mounting / Panel cut-out
1234
H .85 .98 1.22 1.61
I .84 .97 1.13 1.44
J .13 .13 .15 .15
Dim.
(inches)
Shell