Datasheet

Clipper Industrial Plastic Connectors
22
Instruction For Assembly
Insertion and extraction of contacts
Single wires
Contact insertion and extraction is performed without a tool thanks to te retainer plate system.
Insertion
1) With the thumb and index finger, squeeze the
retainer plate flaps and pull backwards : the plate is
then in
the unlocked position.
2) Fully insert the wired contact in the cavity.
3) Repeat the same procedure for the other contacts.
4) Once again squeeze the retainer plate flaps and
push forwards: the plate is then locked and retains
the contacts (90 N of retention force for contacts of
1.6 mm dia.)
5) The plate can only be pushed backed if the
contacts are correctly engaged (backup security)
Extraction
1) With the thumb and index finger, squeeze the
retainer plate flaps and pull backwards : the plate is
then in
the unlocked position.
2) Pull the contact wire: the the contact comes out of
the cavity.
3) Repeat the same procedure for the other contacts.
Special case of jacketed cables
1) Locate the first contact and the corresponding cavity.
2) The wire should described a buckle as describe below.
3) Unlock the retainer plate as described above.
4) Fully insert the wired contact in the cavity.
5) Respect the same procedure for the other contacts
6) Once again squeeze the retainer plate flaps and push forwards : the
plate is then locked
Special case of jacketed cables
7) Manually fully screw the adaptor and the backshell on the connector.
Caution : In the sealed version don’t forget the O-ring.
8) Push forwards the cable of 10 mm in the backshell.
9) Fully screw on the backshell with a wrench while keeping the adaptor
with another wrench.
Note : The plate can only be pushed back if the contacts are correctly
engaged (backup- security)