Datasheet

146
Slide accessories onto the cable
Strip external cable jacket (see dimension H in the table below)
Strip wires and crimp contacts (see pages 140 & 141)
Insert contacts into connector cavities (insert manually or use tool
RTM2
0
5)
Screw adapter to the rear of the connector body and screw cable
gland body to adapter and tighten (recommended torque:
see table below)
Mate the plug with the receptacle to make the following step easier
Slide ferrule inside the cable gland body as shown in g. A
Tighten backshell nut with cable gland body as shown in g. B
(recommended torque: see below).
UTO0 or UTO7 with UTO6 + JCS or JC or JCSL or JCL for Unshielded Cable
Ferrule
Backshell nut
Adapter
UTO6
Cable gland body
H
UTO0
UTO7
Shell size
Adapter
tightening torque
(Nm)
Cable gland body
tightening torque
(Nm)
Backshell nut
tightening torque*
(Nm)
H min. (mm)
JCS/JCSL
JC/JCL
Male Female Male Female
10 6 6 5 21 29 32 39
12 10 10 8 21 29 31 39
14 10 10 8 25 33 39 47
16 14 14 12 32 40 43 51
18 14 14 12 37 45 47 55
20 24 24 20 39 47 49 57
22 24 24 20 41 50 53 61
24 24 24 20 47 55 57 65
Spanner size
Shell size
JCS/JC
JSCL/JCL
Cable gland body Backshell nut Cable gland body Backshell nut
10 17 mm 14 mm 17 mm 17 mm
12 & 14 22 mm 20 mm 22 mm 22 mm
16 & 18 26 mm 24 mm 30 mm 30 mm
20, 22 & 24 33 mm 30 mm 40 mm 40 mm
* Indicative torque, needs to be adjusted depending on the cable used
Assembly Instructions (Continued)
g. A g. B
UTO Series
|
Technical Information