Datasheet

147
Slide accessories onto the cable
Strip external cable jacket (see dimension H and L in the table below)
Strip wires and crimp contacts (
see pages 140 & 141
)
Insert contacts into connector cavities (insert manually or use tool
RTM2
0
5)
Screw adapter to the rear of the connector body and screw cable
gland body to adapter and tighten (recommended torque:
see table below)
Mate the plug with the receptacle to make the following step easier
Slide ferrule inside the cable gland body as shown in g. A
Tighten backshell nut with cable gland body as shown in g. B
(recommended torque: see below).
UTO0 or UTO7 with UTO6 + JCS or JC or JCSL or JCL for Shielded Cable
Shielding ferrule
Backshell nut
Adapter
UTO6
Cable gland body
H
L
UTO0
UTO7
Spanner size
Shell size
JCS/JC
JSCL/JCL
Cable gland body Backshell nut Cable gland body Backshell nut
10 17 mm 14 mm 17 mm 17 mm
12 & 14 22 mm 20 mm 22 mm 22 mm
16 & 18 26 mm 24 mm 30 mm 30 mm
20, 22 & 24 33 mm 30 mm 40 mm 40 mm
Shell size
Adapter
tightening torque
(Nm)
Cable gland body
tightening torque
(Nm)
Backshell nut
tightening torque
(Nm)
H min. (mm)
L min.
(inch)
JCS/JCSL
JC/JCL
Male Female Male Female
10 6 6 5 50 58 61 68 8
12 10 10 8 54 61 65 73 12
14 10 10 8 59 66 73 80 12
16 14 14 12 68 75 79 86 12
18 14 14 12 72 80 83 91 12
20 24 24 20 80 89 90 98 14
22 24 24 20 83 91 94 102 14
24 24 24 20 88 96 98 106 14
* Indicative torque, needs to be adjusted depending on the cable used
g. A g. B
UTO Series
|
Technical Information
Technical Information