Datasheet

148
Slide accessories onto the cable
Strip external cable jacket
Strip wires and crimp contacts (see pages 140 & 141)
Insert contacts into connector cavities (insert manually or use tool
RTM2
0
5)
Tighten backshell with plug and mate plug with a receptacle
(recommended torque values to be applied according to the
table below)
Tighten backshell screws.
Cable clamp
Modular
gasket
UTO0 or UTO7 with UTO6 + AC Backshell Assembly
UTO0
UTO7
UTO6
Shell size Cable clamp tightening torque (Nm)
Clamp (mm)
Min Max
10 4 1.5 5.0
12 5 3.0 8.2
14 5 4.0 10.0
16 9 6.0 13.0
18 9 8.5 16.0
20 11 10.0 16.0
22 13 9.0 19.3
24 15 11.0 20.6
Assembly Instructions (Continued)
UTO Series
|
Technical Information