Datasheet

150
Mate UTO6 (plug) with UTO0 or UTO7 already mounted on a
panel
Slide accessories onto the cable
Strip external cable jacket (see dimension H and L)
Strip wires and crimp contacts (see pages 140 & 141)
Insert contacts into connector cavities (insert manually or use
RTM2
0
5 tool)
Place cable braid shield over inner shielding ferrule (See g. A)
and slide the outer ferrule over the braid shield for UTOS-JCPGN
Screw PG-tube adapter with plug (recommended torque:
see below table)
Tighten PG-nut with PG-tube adapter (See g. B)
Tighten PG-nut screws.
UTO0 or UTO7 with UTO6 + JCPGN Backshell Assembly
Outer shielding
ferrule
Inner shielding
ferrule
PG- nut
PG-tube
adapter
UTO6
Modular
gasket
Washers
g. A g. B
UTO0
UTO7
Ø individual braid shield conductor betweenn 0.3 and 0.5mm
Torques to be applied with the plug mated with the receptacle.
Shell size
PG-tube
tightening torque (Nm)
PG-nut
tightening torque (Nm)
Ø Cable range (mm) H min. (mm)
L min.
(mm)
UTO UTOS
Pin contacts Socket contacts
10 4 1.5 4 to 10 4 to 8.8 26.5 34.2 17.6
12 6 1.5 4 to 11.9 4 to 11.9 26.5 34.2 17.6
14 10 3.5 6.5 to 13.5 6.5 to 13.5 29.6 37.2 20.6
16 10 6.5 6.5 to 16 6.5 to 16 31.6 39.2 22.6
18 10 6.5 6.5 to 16 6.5 to 16 36.9 42.3 26.7
20 15 9 9 to 21 9 to 21 36.4 41.8 26.1
22 15 9 9 to 21 9 to 21 43.4 48.8 33.2
24 15 12 17 to 29.5 17 to 29.5 43.8 49.2 33.6
H
L
Assembly Instructions (Continued)
UTOS-JCPGN
UTO Series
|
Technical Information