Datasheet

165
Souriauoffering:
Standard solutions.
What about using coax contacts ?
Ethernet twisted pairs carry a symmetrical (balanced) signal. Once terminated into a coax contact, the inner core will be protected by a shield - but not
the outer contact. Because of EMI issues, the signal will no longer be balanced. Conclusion - it does not work and is not recommended.
Conclusion
To carry 100Mb/s data signal, 100BaseTX or Fast Ethernet recommends the use of Cat5e connectors as well as Cat5e cable with the support of a 100MHz
signal. Nevertheless, a 100Mb/s signal can be transmitted in certain conditions (short distance, only one connector, lower frequency but a different code)
thru many other connection materials - not necessarily Cat5e rated.
What about using Quadrax contacts ?
The Quadrax contact is used in railway applications because of the use of quad cable. In this specic market, the standard Ethernet twisted pairs wires
cannot be offered, they are too thin and often solid (not stranded).
In the rest of industry, UTP (Unshielded Twisted Pairs) cables are widely used. The Quadrax contact is not designed to terminate them. And thus, are not
advised for industrial applications.
UTO size 12, 10 contacts - Cat5e
Twisted pairs
1 (Pair 1) Ã C
2 (Pair 1) Ã B
3 (Pair 2) Ã G
4 (Pair 2) Ã H
UTO size 16, 19 contacts -Cat5e
Twisted pairs (1Gb/s)
1 (Pair 1) Ã A
2 (Pair 1) Ã B
3 (Pair 2) Ã D
4 (Pair 2) Ã E
5 (Pair 3) Ã G
6 (Pair 3) Ã H
7 (Pair 4) Ã K
8 (Pair 4) Ã L
UTO size 10, 4 contacts - Cat6
Quad cable
1 (Pair 1) Ã A
2 (Pair 1) Ã B
1210
10 Ø 1 (#20)
1619
19 Ø 1.6 (#16)
104
4 Ø 1.6 (#16)
UTO size 10, 6 contacts - Cat5e
Twisted pairs
1 (Pair 1) Ã A
2 (Pair 1) Ã B
3 (Pair 2) Ã E
4 (Pair 2) Ã D
106
6 Ø 1 (#20)
Shielding continuity done in cavity C&F.
Note:Shieldingcanbereplacedby
DC power.
Cat6 if shielding continuity done by other
contact
UTO Series
|
Technical Information
Technical Information