Datasheet

UTO Series
|
Connector
27
UL
44A 600V UL94 V-0
CSA
30A 600V UL94 V-0
IEC
40A 250V 3kV 3
Electrical Characteristics UTO 142G1 Derating Curves
Current use Limited use Not recommended use
Test
conditions
Contact used:
Machined contacts
Wires used:
6mm²
0 20 40 60 80 100
120
0
10
15
20
25
30
35
40
45
50
Current (A)
Ambient Operating Temperature (°C)
5
#8
Contact type AWG
Part number
Max
wire Ø
Max
insulator Ø
Male Female
Crimp
Machined
16
82913601A 82913600A
1.72
6.5
14
82913603A 82913602A
2.22
12
82913605A 82913604A
2.82
10
82913607A 82913606A
3.50
8
82913609A 82913608A
4.35
PCB
Machined
(2)
-
82911685NPC
(1)
82911684NPC
(1)
- -
(1): Example of plating, for other plating options see page 129
(3): For dimensions see page 132
Note: all dimensions are in mm
Contacts
142G1
(Shell size 14, 2 + ground, 3x#8)
40A/250V
per IEC 61984
2 +