Shielded connectors
10. Manually push the shielding ferrule
inside the cable gland body.
11. Make sure the shielding ferrule does
not slide over the cable jacket.
12 . Hold the cable in this position prior
to the assembly of the cable gland
hood.
How to assemble shielded connectors… (con’t)
13 . Hold the cable in the same position
as explained above and tighten
the cable gland hood. The max
tightening torque is indicated in the
table below.
14 . To ease the tightening operation, an
empty receptacle connector can be
used when fixed in a bench.
15. Make sure that the cable is not
twisted during the tightening
operation.
Max tightening torques in Nm
Shell size Cable gland body Cable gland hood
10
65
12
10 8
14
10 8
16
14 12
18
14 12
20
24 20
22
24 20
24
24 20
Above tightening torques are indicative and have to be adjusted in accordance to the cable diameter and application.
Cable gland body