Brochure

161
© 2011 – SOURIAU
Shell size
UTS0
+ UTS6 EN JC & CJC
UTS0
+ UTS6 EN GN
UTS7
+ UTS6 EN JC & CJC
UTS7
+ UTS6 EN GN
A max B max C max D max
8 61.1 - 66.6 -
10 73.2 39.6 77.3 43.7
12 77.6 39.4 81.7 43.5
14 83.5 40 87.6 44.1
18 93.1 - 97.2 -
UTS0 + UTS6
A
B
UTS7 + UTS6
C
D
• Slide accessories on the cable (make sure to keep
compression ring on the grommet)
• Strip external cable jacket
• Strip wires and crimp contacts
• Insert fi rst contact into the grommet (fi rst contact
in cavity A, the contact pierces the grommet, no
tool is required), then insert the contact in the
connector cavity A (insert manually or use tool
RTM2
0
5)
• Place the grommet and compression
ring on the insulator
• Insert the other contacts
• Tight adapter with plug, choose right
seal (waste the other seal), tight nut
with adapter (recommended torque
values to be applied according to
the table - right).
Nut
Adapter + mounted gasket
Grommet + Compression ring
Optional coding ring
Shell
size
Recommended
jacket strip
length (mm)
Adapter
tightening
torque
(Nm)
Nut
tightening
torque
(Nm)
Ø Cable
range
Standard
seal
Ø Cable
range
Reducing
seal
Ø Wire
Male Female
10 21 29 1.5 2 2.5/8.0 1.5/5.0 from
1.7 mm
to
3.0 mm
12 25 33 2 2.5 5.0/12.0 3.0/9.0
14 29 36 3 2.5 7.0/14.0 5.0/12.0
UTS Series
Technical information
UTS 1 GJC / UTS 6 GJC assembly
Mated connector length
Note: all dimensions are in mm
Technical information