The norm is dedicated to connectors with rated voltage above 50V and up to 1000V and rated currents up to 125A per contact. But
depending of your application connectors should be compliant with another standard. This has to be double checked with the customer.
There are lot of constructional requirements and performances specifi ed in that standard. Most of them are illustrated in greater details
hereafter.
Provisions for earthing:
The UTS connector is intended to be used on Class II systems. Even if the purpose of our connector is not to interrupt current, we often
see a need to add a protective earth contact. Then this one shall be a “First mate, last break” style. Critically, among all of the normal
assumptions we make in designing a connector, this contact has to be considered as a live part and must be protected against electric shock
by double or reinforced insulation.
IP Code:
IP is a coding system defi ned by the IEC 60529 to indicate the
degrees of protection provided by an enclosure. The aim of this is to
give information regarding the accessibility of live parts against ingress
of water and other foreign bodies.
1
st
digit Degree of protection 2
nd
digit Degree of protection
0 No protection against accidental contact.
No protection against solid foreign bodies.
0 No protection against water.
1 Protection against contacts with any large area by hand and
against large solid foreign bodies with a diameter bigger than 50
mm.
1 Drip-proof.
Protection against vertical water drips.
2 Protection against contacts with the fi ngers.
Protection against solid foreign bodies with a diameter bigger
than 12 mm.
2 Drip-proof.
Protection against water drips up to a 15° angle.
3 Protection against tools, wires or similar objects with a diameter
bigger than 2.5 mm.
Protection against small solid bodies with a diameter bigger than
2.5 mm.
3 Spray-proof.
Protection against diagonal water drips up to a 60° angle.
4 As 3 however diameter is bigger than 1 mm. 4 Splash-proof.
Protection against splashed water from all directions.
5 Full protection against contacts. Protection against interior inju-
rious dust deposits.
5 Hose-proof.
Protection against water (out of a nozzle) from all directions.
6 Total protection against contacts.
Protection against penetration of dust.
6 Protection against temporary fl ooding.
7 Protection against temporary immersions.
8 Protection against water pressure.
Pressure to be specifi ed by supplier.
9K High pressure hose-proof.
Protection against high pressure water (out of a nozzle) from all
directions.
IP 6 8
First digit
(foreign bodies
protection)
Second digit
(water
protection)
Code letters
(international
Protection)
UTS offers high sealing
performance IP68 / 69K…
Even in dynamic situations.
In addition to the IEC 60529 we conjointly use the DIN 40050 part 9
which are dedicated to road vehicles. The main differences are:
• First digit: 5 replaced by 5K, 6 by 6K. In the DIN the tested
equipment is not depressurized as it is in the IEC.
• Second digit: 5K and 6K has been added and are equivalent
respectively to 5 and 6 but with higher pressure.
9K which represents the High pressure cleaning.
IEC 61984 ed.2.0 “Copyright © 2008 IEC Geneva, Switzerland.www.iec.ch"
IEC 60664-1 ed.2.0 “Copyright © 2007 IEC Geneva, Switzerland.www.iec.ch”