Datasheet

UTS Series
|
Connector
115
UTS 1210 - 12E10/12D10 Derating Curves
Test
conditions
Contactused:
Machined contacts
Wiresused:
0.518mm²
Current use Limited use Not recommended use
0 20 40 60 80 100
0
2
1
4
3
6
5
8
7
10
9
12
13
11
Current (A)
Ambient Operating Temperature (°C)
120
IEC
6A 50V 1.5kV 3
Electrical Characteristics
UTS 1210
UL
5A 250V UL94 V-0
CSA
4A 250V UL94 V-0
UTS 12E10/12D10
UL
4.5A 250V UL94 HB
CSA
4.5A 250V UL94 HB
Contacts
1210 - 12E10/12D10
(Shell size 12, 10x#20)
#20
Contact type Plating Cable acceptance (AWG) Wire stripping length
Handsolder
Loaded in the connector Min 0.4µ gold over 0.8µ Ni 22 to 18 3.8 mm
(1): Example of plating, for other plating see page 164 (2): Loose piece contact available if putting L. Example: SM20WL3TK6 (3): For dimensions see page 168 Note: all dimensions are in mm
#20
Contact type
Wire size Part number
Max
wire Ø
Max
insulator Ø
AWG mm² Male Female
Crimp
Machined
26-24 0.13-0.25
RM24W3K
(1)
RC24W3K
(1)
0.80 1.60
22-20 0.32-0.52
RM20W3K
(1)
RC20W3K
(1)
1.15 1.60
20-18 0.50-0.93
RM18W3K
(1)
RC18W3K
(1)
1.30 2.10
Stamped & Formed reeled
contacts
See note (2) for loose piece
26-24 0.13-0.25
SM24W3TK6
(2)
SC24W3TK6
(2)
- 0.90-1.60
26-24 0.13-0.25
SM24W3S26
(2)
SC24W3S25
(2)
- 0.90-1.60
22-20 0.32-0.52
SM20W3TK6
(2)
SC20W3TK6
(2)
- 1.20-2.10
22-20 0.32-0.52
SM20W3S26
(2)
SC20W3S25
(2)
- 1.20-2.10
PCB
Machined
(3)
- -
RMW5016K RCW5016K
- -
10 contacts
6A/50V
per IEC 61984
10