Technical Information
UTS1GJC or UTS6GJC Assembly
Mated Connector Lengths
Assembly Instructions (Continued)
Slide accessories onto the cable (make sure
to keep compression ring on the grommet)
Strip external cable jacket
Strip wires and crimp contacts
(see pages 176 & 177)
Insert rst contact into the grommet (rst
contact in cavity A, no tool is required).
Then insert the contact in the connector
cavity A (insert manually or use tool RTM2
0
5)
Place the grommet and compression ring on
the insulator
Insert the other contacts
Tighten adapter with plug UTS6 or receptacle
UTS1, choose right seal(waste the other seal)
Tighten the nut to rear of either UTS1 or
UTS6 (recommended torque values to be
applied according to the table right).
Nut
Adapter + mounted gasket
Grommet +
Compression ring
Shell
size
Recommended
jacket strip
length (mm)
Adapter
tightening
torque
(Nm)
Nut
tightening
torque
(Nm)
Ø Cable
range
Standard
seal
Ø Cable
range
Reducing
seal
Ø Wire
Male Female
10 21 29 1.5 2 2.5/8.0 1.5/5.0 from
1.7 mm
to
3.0 mm
12 25 33 2 2.5 5.0/12.0 3.0/9.0
14 29 36 3 2.5 7.0/14.0 5.0/12.0
Coding ring
(optional)
Cable ranges
Reducing Standard
Cable
range
UTS6
UTS1
Shell size
UTS
0
+ UTS6 JC & GJC
UTS
0
+ UTS6 GN
UTS7
+ UTS6 JC & GJC
UTS7
+ UTS6 GN
A max B max C max D max
8 61.1 - 66.6 -
10 73.2 39.6 77.3 43.7
12 77.6 39.4 81.7 43.5
14 83.5 40 87.6 44.1
18 93.1 - 97.2 -
A
B
C
D
Note: all dimensions are in mm
UTS0 + UTS6
UTS7 + UTS6