Datasheet
184
UTS Series
|
Technical Information
UTS1GJC or UTS6GJC Assembly
Mated Connector Lengths
Assembly Instructions (Continued)
• Slide accessories onto the cable (make sure
to keep compression ring on the grommet)
• Strip external cable jacket
• Strip wires and crimp contacts
(see pages 176 & 177)
• Insert rst contact into the grommet (rst
contact in cavity A, no tool is required).
Then insert the contact in the connector
cavity A (insert manually or use tool RTM2
0
5)
• Place the grommet and compression ring on
the insulator
• Insert the other contacts
• Tighten adapter with plug UTS6 or receptacle
UTS1, choose right seal(waste the other seal)
• Tighten the nut to rear of either UTS1 or
UTS6 (recommended torque values to be
applied according to the table right).
Nut
Adapter + mounted gasket
Grommet +
Compression ring
Shell
size
Recommended
jacket strip
length (mm)
Adapter
tightening
torque
(Nm)
Nut
tightening
torque
(Nm)
Ø Cable
range
Standard
seal
Ø Cable
range
Reducing
seal
Ø Wire
Male Female
10 21 29 1.5 2 2.5/8.0 1.5/5.0 from
1.7 mm
to
3.0 mm
12 25 33 2 2.5 5.0/12.0 3.0/9.0
14 29 36 3 2.5 7.0/14.0 5.0/12.0
Coding ring
(optional)
Cable ranges
Reducing Standard
Cable
range
UTS6
UTS1
Shell size
UTS
0
+ UTS6 JC & GJC
UTS
0
+ UTS6 GN
UTS7
+ UTS6 JC & GJC
UTS7
+ UTS6 GN
A max B max C max D max
8 61.1 - 66.6 -
10 73.2 39.6 77.3 43.7
12 77.6 39.4 81.7 43.5
14 83.5 40 87.6 44.1
18 93.1 - 97.2 -
A
B
C
D
Note: all dimensions are in mm
UTS0 + UTS6
UTS7 + UTS6