UTS 14E12/14D12 Derating Curves
UL
4.5A 250V UL94 HB
CSA
4.5A 250V UL94 HB
IEC
4A 50V 1.5kV 3
Electrical Characteristics
Current use Limited use Not recommended use
Test
conditions
Contactused:
Machined contacts
Wiresused:
0.518mm²
0 20 40 60 80 100 120
0
4
2
6
8
10
12
14
Current (A)
Ambient Operating Temperature (°C)
#16
Contact type Plating Cable acceptance (AWG) Wire stripping length
Handsolder
Loaded in the connector Min 0.4µ gold over 0.8µ Ni 18 to 14 5.0 mm
PCB
Machined
(1)
Min 0.4µ gold over 0.8µ Ni - -
#20
Contact type Plating Cable acceptance (AWG) Wire stripping length
Handsolder
Loaded in the connector Min 0.4µ gold over 0.8µ Ni 22 to 18 3.8 mm
PCB
Machined
(1)
Min 0.4µ gold over 0.8µ Ni - -
Contacts
14E12/14D12
(Shell size 14, 8x#20, 4x#16)
(1): For dimensions see page 169
12 contacts
4A/50V
per IEC 61984