Datasheet

UTS Series
|
Connector
131
UTS 12E14/12D14 Derating Curves
UL
4.5A 250V UL94 HB
CSA
4.5A 250V UL94 HB
IEC
5A 32V 1.5kV 3
Electrical Characteristics
Current use Limited use Not recommended use
Test
conditions
Contactused:
Machined contacts
Wiresused:
0.518mm²
0 20 40 60 80 100 120
0
1
3
5
7
8
4
2
6
9
11
10
Current (A)
Ambient Operating Temperature (°C)
12E14/12D14 (Shell size 12, 14x#20)
Contacts
#20
Contact type Plating Cable acceptance (AWG) Wire stripping length
Handsolder
Loaded in the connector Min 0.4µ gold over 0.8µ Ni 22 to 18 5 mm
PCB
Machined
(1)
Min 0.4µ gold over 0.8µ Ni - -
(1): For dimensions see page 169
14 contacts
5A/32V
per IEC 61984
14