- Deep Fat Fryer Owner's Manual

t--a---
--r
FRONT VIEW
DIMENSIONS:
DEEP FAT FRYER
INSTALLATION
SPECIFICATIONS
TOP VIEW
SIDE VIEW
( ) = Millimeters
NOTEI Model 14 Fryers - 14” (356 mm) wide x 14” (356 mm) deep; Model 18 Fryers - 18” (457 mm) wide x 18” (457 mm) deep,
‘Model 14-32 comes standard with a shelf splasher- overall height is 56.5” (1435 mm).
*Model 14-32 only has %” gas connection: I = lo” (254 mm), J = 1.75” (44 mm).
UTILITY INFORMATION:
GAS - 14-32; 14-36; 14-42 -Total BTU 90,000
1836; 18-42-Total BTU 112,500
14-32 has %” connection - male.
Models 1436,14-42, 18-36 & 18-32 have 1%” connection (1 end male, 1 end female).
0 NATURAL
0 PROPANE
Required operating pressure: Natural Gas 4” W.C.; Propane Gas 10”
W.C.
UNrrS WITH OPTIONAL REAR GAS CONNECTION:
SIDE VIEW FOR
REAR VIEW FOR
14-36”. 14-42”.
14-36, 14-42,
18-36”. 18-42”
18-36, 18-42
No external electrical power supply is required for the units.
NOTE: If this equipment is being installed over 2,000 feet altitude and was not so specified
on order, contact Southbend Service Department. Failure to install with proper orifice sizing
may void the warranty.
DEEP FAT FRYER
SECTION
ONE - INSTALLATION
PAGE 1