Refrigerated Base Self Contained Spec Sheet

1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
www.yatesgd.com www.yatesgraphicdesign.com
Form PSCR Rev 6 (August/2014)
72" (1829) 84" (2134)
64" (1524)
48" (1219)
108" (2743)
96" (2438)
36" (914)
120" (3048)
25"
(635)*
Each 18" drawer
holds one pan
18" (457)*
Each 26" drawer holds
two pans front-to-back
26" (686)*
Each 31" drawer holds
two pans side-by-side
31" (787)*
TOP VIEW Showing Extended Drawers
32" (813)
RIGHT SIDE
26"
(660)
32.5" (826)*
6" (152)
Power cord and condensate drain tube
located behind compressor area.
1" (25)
Tubing Cover for 60” and larger units.
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
MISCELLANEOUS
UTILITY INFORMATION
- If casters are used with ex hose, a restraining
device should be used to eliminate undue strain on
the ex hose.
- Minimum clearance on rear is 2” (51 mm)
- Modular range top sections can be mounted
directly on top using an insulated base adapter.
- Can be part of sectional battery, provided that
the adjoining base sections are insulated, or do not
produce heat.
- Avoid locating where the temperature will drop below
55°F or rise above 90°F
- Check local codes for re and sanitary regulations.
NOTICE:
Southbend has a policy of continuous product
research and improvement. We reserve the right to
change specications and product design without
notice. Such revisions do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for previously purchased equipment.
All models have a six foot power cord with a grounded plug to recieve 50Hz or 60Hz
single-phase AC. Condensate drain is a 1/2” inside diameter vinyl tube.
OPTIONS AND ACCESSORIES
The drawer-front width, drawer-extension distance, and overall depth may vary (the maximum values are specied and shown)
Electric condensate evaporator pan (32”, 36”, 48”, 60”
& 64”)
Cable restraint kit (to restrict movement when on casters)
Casters -front two casters lock
Open-frame base with casters
Model Width
# of Drawers
# of
Pans
Cooled Volume
cu. ft (cu. m.)
Cooling Cap
BTU/hour
Electricity
120V Amps
Compressor
Motor
Shipping
Weight
18” 26” 31”
20032SB
32” 2 - - 2
4 (0.11) 1450 8
1/4 H.P.
340 lbs
(154 kg)
20036SB
36” 2 - - 2
4 (0.11) 1450 8
1/4 H.P.
340 lbs
(154 kg)
20048SB
48” - 2 - 4
6.7 (0.19) 1670 8
1/4 H.P. 410 lbs
(186 kg)
20060SB 60” - - 2 4 10 (0.28) 1802 8
1/4 H.P.
550 lbs
(249 kg)
20064SB
64” - - 2 4
10 (0.28) 1802 8
1/4 H.P.
550 lbs
(249 kg)
20072SB
72” - 4 - 8
13 (0.37) 1875 10.1
1/3 H.P.
650 lbs
(295 kg)
20084SB
84” - - 4 8
16 (0.45) 1920 10.1
1/3 H.P.
745 lbs
(338 kg)
20096SB
96” 2 4 - 10
18 (0.51) 1955 20
1/2 H.P.
855 lbs
(388 kg)
20108SB
108” - 6 - 12
22 (0.62) 1955 20
1/2 H.P
960 lbs
(435 kg)
20120SB
120” 4 4 - 12
25.5 (0.72) 2000 20
1/2 H.P
1075 lbs
(488 kg)
Amperage is approximate and is for compressor only. Do not use for breaker sizing.