SCHEDULED MAINTENANCE
Table 4.1 - Preventative Maintenance Action Index
1.
2.
3.
4.
Weekly
Monthly
Annually
Three-year Frequency
a. Inspect condenser coil
i
to make certain that air flow is not
hampered and that it is clear of dust and debris.
a. Inspect and clear drain line.
b. Check the liquid refrigerant sight glass
i
to make certain that
the system is completely charged.
c. Clean the interior of the cabinet with a mild soap and warm
water solution. Be certain to dry thoroughly.
d. Check both the condenser fan motor
i
and the evaporator
fan motor to make certain that they are operational and that
the fans are tight and secure.
e. Clean door gaskets and breaker strips with a damp cloth.
f. Clean exterior of cabinet with mild soap and warm water.
Dry thoroughly.
a. Check all joints and fittings for any signs of leaks or fatigue.
b. Inspect electrical connections to confirm that there is good
contact and that wires are neither weakened nor frayed.
c. Check the integrity of the cabinet.
a. Replace door gaskets.
b. Inspect motor shafts
i
for noise or wear.
c. Inspect electrical controls and wiring.
d. Inspect drawer slides.
e. Recalibrate thermometer.
i
If supplied with a condensing unit