Manual

GAS CONVECTION OVENS
OPERATOR’S MANUAL 1181887 REV 9 (10/14)
PAGE
4
OF 44
SPECIFICATIONS
NOTICE
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc.
states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation
requirements for equipment. Therefore, installations should comply with all local codes.
Southbend reserves the right to change specications and product design without notice. Such revisions do not entitle
the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
This product is intended for commercial use only, not for household use.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2,
as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve `
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45
kPa).
SPECIFICATIONS
WARNING
There must be adequate clearance between the left side of the ovens and combustible construction..
Minimum Clearance from
Combustible Construction
Minimum Clearance from
Non-Combustible Construction
Back 0” 0”
Right Side 0” 0”
Left Side 2” 0”
Floor 0” 0”
Adequate clearance must be provided in the aisle to allow the doors to open sufciently to permit the removal of the
racks and for serviceability.
Although no clearance is required behind the motor on the rear of the oven, care must be taken to provide adequate
air circulation to prevent the motor from overheating.
Do not locate the oven adjacent to any high heat or grease-producing piece of equipment, such as a range top,
griddle, fryer, etc., that could allow radiant heat to raise the exterior temperature of the oven above 130°F (54°C).
DO NOT MOUNT ABOVE OTHER COOKING EQUIPMENT.
MINIMUM CLEARANCES
GAS SUPPLY
The serial plate is located inside the lower front panel. It indicates the type of gas the unit is equipped to burn. All
Southbend equipment is adjusted at the factory. Check type of gas on serial plate.
These models are design-certied for operation on natural or propane gases. For natural gas, the regulator is set to
deliver a 4.0” W.C. pressure to the manifold. For propane gas, it is set to deliver 11” W.C.