Installation Guide
SOUTHWEST WINDPOWER DOCUMENT 0228 REV A
17
Once the tower is straight, make sure that all the cable clamps are tight. If the tower is to be
lowered, only undo the bolt side cable so that, when the tower is re-erected, only that cable will
need to be readjusted.
Step 10: Junction Box and Lightning Arrestor Installation
A junction box for the wire connections can be attached to the tower base. A lightning arrestor
can be installed on this box as well. We recommend an all weather box approved for outdoor use
and of sufficient size for the wires to be connected. This should be available from your local
electrical supply store. For the wire connections we recommend copper split bolts also available
from your local electrical supply store. One hole of the junction box should hold a short threaded
nipple attached to 1 ½ in. (nominal size) CPVC pipe adapter. This adapter will fit into the base of
the tower and can be locked in place with a set screw. The other two holes should hold the
lightning arrestor (if used) and a flexible conduit connector to route the wires into the ground.
Generally, direct burial wires are used from the batteries to the tower base. These wires should be
buried from the batteries (or shed / house) out to the tower base where they are routed into the
junction box. The wires coming out of the junction box should all be trimmed to about 5 in. The
turbine wires and the lightning arrestor should all be stripped and connected together with the
split bolts. Once connected, they should be thoroughly wrapped with electrical tape and the lid to
the junction box secured.
Grounding
To properly ground the tower to the earth a six to eight foot ground rod must be installed as close
to the tower base as possible. A 10 gauge or larger wire should be firmly attached to the tower
pipe near the bottom of the tower and clamped to the ground rod. The junction box should also
be connected to this ground.
Maintenance
Periodically check to see that the guy wire tension is set properly and that the cable clamps have
not loosened. There is no other maintenance required for this tower system.