Operating Instructions

www.rvpower.southwire.com
For use with Automatic Transfer Switch (ATS) unit 40350-RVC or 41390-RVC, the Remote LCD Display is
connected via an RJ12 (6 pin) connector cable to conveniently monitor your electrical power anywhere inside
your RV remotely from the location of the ATS.
The Remote Power Control allows you to see detailed information such as voltages for Line 1 and Line 2,
(typically 110-120VAC), current draws (0 to 50Amps), and status and conditions of the ATS, including time and
date. Electrical faults, such as low voltage or an open ground connection, that cause the ATS to shut off power
are shown on the remote display, allowing you to retrieve via the joystick a log of fault conditions kept by the ATS
of electrical power at your location.
This is a helpful diagnostic tool that allows you to comprehend and correct problems with your RV’s power. The
display also features a right/left navigation lever allowing navigation through the various screens.
Complete set of features and information
displayed includes the following:
Main Screen: Display of normal operating voltages
and currents, for example 120V 25Amps for each Line
(240V system). Shore power or generator power.
Main Screen: Display of faulty power conditions
responded to by ATS such as low voltages, high
voltages, open ground, open neutral, reverse polarity,
high frequency, etc.
Main Screen: Display of delay condition when
recovering from faulty conditions.
L1/L2 Volt and Current Screens: Displays line
1/2 voltage or current. This is handy as it allows you
to view the voltage or current when there is a fault
condition being displayed on the main screen.
Faults Screen: Allows you to view a history of
up to 50 faults which have been logged by the ATS.
Each fault that has been logged contains the fault, the
voltages and currents at the time of the fault, and the
time and date when it occurred.
Time/Date Screen: Displays the current time and
date and allows you to set the current time and date
on the ATS unit.
Joystick Lever: to navigate through screens and
set the time and date.
INSTALLATION & OPERATING
INSTRUCTIONS
For technical assistance, please call 1-800-780-4324 x 20311
Manufactured by Southwire Company, LLC, 4525 140th Avenue North, Suite 900, Clearwater, Florida 33762
© 2017 Southwire Company, LLC. All rights reserved. * Trademark of Southwire Company, LLC. Registered in the United States.
505-00065E
Model 40299
Remote Power Control Monitor
LCD Display w/Navigation
Please read these instructions carefully.
In the event you have any questions concerning use or care of this product, please contact Southwire at 1-800-780-4324.
MADE IN
HONDURAS
40299
Navigation
Fault Screen
Up
Screen
Down
Screen
FOR YOUR RECORDS
MODEL NO: ___________________
DATE PURCHASED: ____________
WHERE PURCHASED: __________

Summary of content (2 pages)