User's Guide
V150708
CN1
CN9
CN2
CN5
DC12V
Card Present
WG-Buzzer
WG-GLED
RLED
GND
GND
Reserved
WG0
WG1
CN4
LA+ (FW Only)
LB- (FW Only)
13.56MHz
125kHz
13.56MHz
AR-888 (K/U)
SET1 (Format)
SET2 (Format)
W
G
R
ST
WG Reader
29 20
GLED Input (Active High)
RLED Input (Active High)
Basic Commands
Wiring Diagrams
www.soyal.com
Door Lock Wiring
Door Sensor Wiring
WG Reader Wiring
Networking Connection Wiring
Exit program mode
PIN=0000 (Disable)
PIN=0000 (Disable)
Add PIN User
M4/M8 Mode
13
00001 4321
M6 Mode
17
4321
Add Card+PIN User
Set up Door Relay Time
Set up Door Close Time
TTT: 001~600=1~600 sec.
601~609=0.1~0.9sec.
000=On/ Off (Latch)
TTT: 001~600=1~600 sec.
Add Card User
Ex.:
00001 start user address at
00001 and scanned 50 pcs of
card one by one; next time, input
19*00051*00001#
User Range: 00000~03000
(Please list down each User Address
and its Card ID)
M4/M8 Mode
19
00001 00001
M6 Mode
(Must set up 17*0000#)
22 1
Delete Card User
Delete All User Cards
Reset to Factory
Default Value
Ex.:
00001 start user address at 00001
00005 end user address at 00001
Totally 5 user cards will be
disabled.
User Range: 00000~03000
(Delete all cards and parameters)
M4/M8 Mode
10
00001
9
00005
M6 Mode
10
00001 00005
29 29
Attach/Present Card
One by One
02 007
18 015
M4/M8 Mode (4/8 beeps
while engtering progrm
mode)
12
00001 1234
M6 Mode (6 beeps)
15
1234
CN1
CN9
CN2
CN5
CN4
DC12V
WG0
Alarm
Buzzer
PB
GLED
Door SEN.
RLED
COM
N.C.
LA+
N.O.
LB-
GND
GND
Duress
Arming
WG1
AR-888 (H)
Stand-Alone
/Networking
Controller
Electric Bolt
or
Magnetic Lock
Door Contact
N.C.
Electric Strike
AR-888 (K/U)
125kHz WG/ABA/RS232 Format
(Change by shorted on PCB)
Format WG RST/Bits
WG 26
Open Open
WG 34
Open Short
RS-232
Short Open
ABA-8
Short Short
ABA-10
Short Open
AR-888 (K/U)
13.56MHz WG/ABA Format
(Change by wires connection)
Format SET 1 SET 2 Note
WG 26 Open Open HEX
WG 34 Open To GND HEX
ABA-10 To GND Open BCD10
ABA-5-5 To GND To GND BCD
Exit Button Wiring
CN1
COM
N.C.
GND
DC12V
N.O.
Push Button
AR-PBI888
At every 32 units or at every300M
connection to add a RS485 Booster.
Suggest to connect up to 32 units for
each CH of AR-727CM
Notice:
032=Node ID of Access Controller
032=Virtual 716E Node ID
032=Door number
(All Range:001~254)
009=Node ID of Access Controller
Range: 001~254)
Set up Node ID
Ex. Node 32 connected to PC
00 032 032 032
Ex. Node 9 conected to 716E
00 009
Alarm Output 1- Alarm Wiring
N.C.
N.O.
COM
CTL
12V
Enable Door Open Too Long Alarm
24 064
(Enable)
24
000
(Disable)
Stop Alarm by Push Button
Alarm Output 2- WG Dual Door
Control Wiring
Lock
28 064
(Enable)
28
128
(Disable)
Occupied Alarm Output to support
SET
Floor/ Stop
F F F F F F F F
0 8 7 6 5 4 3 2 1
1 16 15 14 13 12 11 10 9
2 24 23 22 21 20 19 18 17
3 32 31 30 29 28 27 26 25
Alarm Output 3-Lift Control Wiring
B-
A+
Host
AR-401RO16B
Node ID 001
Lift
Controller
B-
A+
AR-321L485
Converter
RX
24 002
(Enable)
24
000
(Disable)
Enable Life Control
21 UUUUU S FFFFFFFF
Assign Floor User (Multi-Floor)
S=Set=0~3
FFFFFFFF=0 (Disable) / 1 (Enable)
Ex. Assign user
address 1 to access
to 1, 3, 5, 7 oor
21*00001*0*01010101
#
Assign Users (Single Floor)
27 UUUUU FF
UUUUU=User Address=00000~03000
FF=Floor number=1~32
123456
Enter program mode
Change program code
Input 6-digit PWD twice
POWER
12VDC
GND
GLED Input (Active High)
RLED Input (Active High)
Hall-Effect Sensor (Active Low)
Hall-Effect Sensor (Active Low)
External
Relay
Alarm
Enable Arming while exit
program mode
N.C.
N.O.
COM
CTL
12V
External
Relay
Flush-Mounted Series
09 654321654321
AR-888(H)
Node ID
002
AR-888(H)
Node ID
032
AR-888(H)
Node ID
254
B-
A+
B-
A+
B-
A+
Host
CH1
CH2
Each CH up to
8 Nodes
Node ID
001
Multi-Door
Controller
Converter
AR-321CM
AR-727CM