SEKURY D500 SAI/UPS GB User manual
Sekury D500 Series KEEP THESE INSTRUCTIONS - Please read the following information carefully and save this manual for further reference. Disregard of these safety notes may endanger life or health, as well as the function of the equipment and the safety of your data. The Sekury D500 UPS Series provides full protection to your computer and peripherals, such as TFT screens, modems, routers and etc. Moreover, prevents data loss generated by blackouts, surge and other electrical disturbances.
2. PRODUCT OVERVIEW Front View: 1 1 Power Switch 2 3 2 UPS status LED indicator 3 Fault/Battery status LED indicator (Check the Indicator & Alarm Table for the details) Back View: 1 3 1 AC input 2 Protected Schuko outlets 3 Fuse 2 3. INSTALLATION AND INITIAL SETUP Before installation, please inspect the unit. Make sure that the UPS it’s in perfect conditions and free of any kind of external damages.
Connection to mains and charging Plug in the AC input cord to the wall outlet. This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load (no electrical devices such as computers, monitors, etc.) connected.
Indicators & Alarm Table Mode Visual Indicator Alarm AC Mode Blue LED lighting Off Battery Mode Blue LED flashing every 10 seconds Sounding every 10 seconds Low battery Blue LED flashing every second and Red LED lighting Sounding every second Fault Red LED lighting Continuously sounding 4. IMPORTANT SAFETY INSTRUCTIONS ≥≥ Risk of Electric Shock. Do not open the UPS (except for battery replacement following the safety norms). ≥≥ Risk of Electric Shock.
≥≥ A battery can present a risk of electric shock and high short circuit current. The following precaution should be observed before replacing batteries: • Remove watches, rings, or other metal objects. • Use tools with insulated handles. • Wear rubber gloves and boots. 5. TROUBLESHOOTING Problem Possible Cause Low battery. No LED display on the front Battery fault. panel. Solutions Charge the UPS at least 8 hours. Replace the battery with the same type of battery. The UPS it’s not turned on.
6. SPECIFICATIONS Model CAPACITY Sekury D500 500 VA /240 W Input Voltage 220/230/240 VAC Frequency 50 Hz/ 60 Hz Voltage Range 170-280 VAC Output Voltage Frequency Transfer Time Output waveform 230V AC 50 Hz +/-1% Typical 2-6 ms Modified sinusoidal BATTERY Type Charging Time Sealed, acid battery, 12 V/ 7 AH x 1 8 hours to recover 90% of the capacity PHYSICAL Dimensions 228 x 82.5 x 207 mm Weight 2.
Specifications are subject to change without notice. © 2009 by Soyntec®. All rights reserved. Trademarks. All company, brand and product names are trademarks or registered trademarks of their respective companies. DECLARATION OF CONFORMITY Manufacturer Name: Energy Sistem Soyntec S.A. Address: Pol. Ind. Finestrat C/ Calpe esq.