User's Manual
Table Of Contents
- Telemetry Transmitter
- Table of Contents
- Conventions Used in This Manual 1-1
- Nurses 1-7
- Monitor Technicians 1-7
- Biomedical Engineers 1-7
- Physicians 1-7
- Patients 1-7
- Sources of Interference 1-8
- Potential Sources of Damage 1-8
- Optional Leadwire Grouper 2-3
- Leadwire Color Codes 2-4
- Telemetry Channel Label 2-5
- Adult Electrode Placement 3-3
- Lead Fault Indication 3-4
- Noise Detection 3-4
- False Alarms 3-5
- Traditional Pulse Oximetry 3-5
- Electrodes, Leadwires, Sensors, and Sensor Cables 3-7
- Electrodes, Leadwires, Sensors and Sensor Cables 3-8
- Spacelabs Healthcare Technology 3-13
- Additional Information for Telemetry Products 3-13
- Telemetry 3-13
- Heart Rate Averaging 3-13
- Spacelabs Healthcare SpO2 Sensors 3-18
- Additional Information 3-18
- Transmitter Batteries 4-1
- Host Monitors 4-2
- Telemetry Receiver Module 4-2
- Assigning a Telemetry Channel 4-3
- Top, Front and Bottom View (96281-C) 4-4
- Rear View (96281-C) 4-5
- Front View (96281-A) 4-6
- Battery Compartment (96281-A, 96281-B, 96281-C) 4-7
- ECG 4-12
- SpO2 4-14
- Cleaning/Disinfecting 5-1
- Recommended Cleaning Solutions 5-2
- Basic Cleaning and Low-level Disinfection 5-3
- Cleaning ECG Leadwires 5-3
- Cleaning Buttons 5-3
- Cleaning the Battery Cover 5-3
- Table 1—Electromagnetic Emmissions A-1
- Table 2—Electromagnetic Immunity A-2
- Table 2—Electromagnetic Immunity (continued) A-3
- Table 3—Separation Distances A-4
- Introduction
- About the Transmitters
- ECG and SpO2
- ECG Overview
- Patient Preparation and Electrode Application
- To Set Up ECG Monitoring
- ECG Problem Solving
- SpO2 Overview
- Warnings and Cautions for SpO2
- Setting Up SpO2 Monitoring
- Ensuring Accurate SpO2 Monitoring
- SpO2 and Pulse Rate Specifications
- Using the Sensorwatch Feature
- Enabling and Adjusting Alarms
- Data Averaging
- Display Details at the Host Monitor
- Printing SpO2 Waveforms
- SpO2 Messages at the Host Monitor
- Sensors
- SpO2 Alarm Delays
- SpO2 Troubleshooting Guide
- Basic Operations
- Getting Started
- Basic Components
- Selecting Options for Leads
- Basic User Actions
- Basic Modes of Operation
- View Mode
- Status Messages at the Host Monitor
- Telemetry Transmitter with ECG Only Troubleshooting Guide
- Telemetry Transmitter with Display Troubleshooting Guide
- Telemetry Transmitter with Display and SpO2 Troubleshooting Guide
- Cleaning, Disinfecting, and Sterilization
- Appendix A — Guidance and Manufacturer’s Declaration
- Appendix B — Symbols
TELEMETRY TRANSMITTER (96281) OPERATIONS MANUAL 5-1
Cleaning, Disinfecting,
and Sterilization
Cleaning Products Not Recommended for Use
Warnings:
• Do not use Accelerated Hydrogen Peroxide (AHP) and quaternary ammonia-based
products to clean the transmitter, leadwires, cables, or sensors. Common quaternary
ammonia germicidal products include Cavicide, Virex, Virex 256, SaniCloth, and
Sanicloth Plus.
• These chemicals attack the plastics used in patient monitors and cables, and will
cause serious safety hazards as the electrical insulating properties and structural
integrity of the equipment break down.
• These germicidal products are safe for use ONLY on hard, non-porous surfaces,
such as linoleum floors, formica countertops, and stainless steel.
Cleaning the Display
Clean the display with a soft cloth moistened with either 70% isopropyl alcohol solution or
soapy water.
Notes:
Obey your hospital protocol for the handling of blood and body fluids.
Transmitter, Leadwires, Cables, and Sensors
Cleaning/Disinfecting
Warnings:
• Use only recommended cleaning solutions, or you may void the manufacturer’s
warranty.
• Harsh chemical agents degrade plastics and compromise the safety of the device.
Some germicidal and other harsh cleaning compounds are known to damage some
plastics by weakening the structural integrity and compromising the electrical
insulating properties.
• Disconnect the equipment from the patient before cleaning.
D R A F T
22 June 2012