QuickLogic EOS S3 Ultra Low Power multicore MCU datasheet - Version 3.3d  27-129 
© 2020 QuickLogic Corporation   
www.quicklogic.com  74
 Power-Down Sequence of Crystal Clock 
The recommended power-down sequence of the EOS S3 when crystal clock is used as input to XTAL_IN is shown in the 
following figure.
Figure 47: Power-Down Sequence of Crystal Clock 
Crystal Clock (32 kHz)
AVDD
LDO_VIN/VDD1/
VDD2
VCCIO
A
NOTE: Recommended power down sequence: VCCIO > VDD/AVDD. Power down VCCIO before VDD. Powering down all 
power supplies at same time is allowed. Powering down AVDD/VCCIO together then VDD is allowed. 
When  the  system  requires  intermittent  power  up/down,  the  power  down  duration  for  AVDD,  ramp  time,  and 
temperature of the input crystal clock are shown in the following table. 
Table 21: Power-Down Duration Time for AVDD
AVDD  Ramp Up Time  Temperature  AVDD Power-Down Time  AVDD @ 90% to HOSC Lock
a
3.3 V  Any 
–20 
℃
 or higher 
Not required  Not more than 1.5 seconds 
1.8 V  Any 
–20 
℃
 to less than 0 
℃
More than 40 seconds  Not more than 1.5 seconds 
1.8 V  Any 
0 
℃
 to less than 25 
℃
More than 5 seconds  Not more than 1.5 seconds 
1.8 V  Any 
25 
℃
 to 85 
℃
More than 1 second  Not more than 1.5 seconds 
1.8 V  Less than 100 µs
–20 
℃
 to 85 
℃
Power down must be less 
than 100 milliseconds or 
more than 1 second 
Not more than 1.5 seconds 
a. For more information, see row J in 
Table 20
. 