Data Sheet
MLX90393 
Micropower Triaxis® Magnetometer Datasheet 
STARTUP
LOAD CALIB DATA
IDLE
LP_OSC disabled
STANDBY
LP
_OSC enabled
POR
VDD > V
POR_LH
Burst
mode
WOC_
IDLE
LP
_OSC enabled
WOC
mode
SM mode
EX
TIME
m*T
CONVM
 + 
T
CONVT
T
ACTIVE
T
STBY
T
POR
EX
~T
INTERVAL
~
T
INTERVAL
&& Burst mode
T?
X
?
Y?
Z?
MDATA ?
MEASURE
LP_
OSC & MAIN
_OSC 
enabled
Figure 4: Top-level state diagram with indication of timings 
7.1 Burst mode 
When the sensor is operating in burst  mode, it will make conversions at specific time intervals. The 
programmability of the user is the following: 
•  Burst speed (T
INTERVAL
) through parameter BURST_DATA_RATE 
•  Conversion time (T
CONV
) through parameters OSR, OSR2 and DIG_FILT 
•  Axes/Temperature (MDATA) through parameter BURST_SEL or via the command argument (ZYXT) 
Whenever the MLX90393 has made the selected conversions (based on MDATA), the DRDY signal will be set 
(active H) on the INT and/or INT/TRG pin to indicate that the data is ready for readback. It will remain high 
until the master has sent the command to read out at least one of the converted quantities (ZYXT). Should 
3901090393    Data Sheet 
Rev002  Page 10    Feb-2015 