Data Sheet
MLX90393 
Micropower Triaxis® Magnetometer Datasheet 
Parameter  Remark  Min  Nom  Max  Unit 
Startup 
T
POR
  Power-on-reset completion time    0.6  1.5  ms 
External Trigger 
T
TRIG
  Trigger pulse width (active high)  0.01    250  us 
(1)  This  conversion time is defined as the time to acquire a single axis  of the magnetic flux density. 
When measuring multiple axes, they are obtained through time-multiplexing, i.e. X(t), Y(t+T
CONVM
) 
and Z(t+2*T
CONVM
). The conversion time is programmable through parameters OSR and DIG_FILT for 
magnetic conversion time and OSR
2
 for temperature conversion time. The conversion sequence is 
always TXYZ, the opposite of the ZYXT argument of the command set. 
(2)  The time T
INTERVAL
  is defined as the time between the end  of one set of measurements (any 
combination of TXYZ) and the start of the following same set of measurements in BURST and WOC 
mode. As a result of this, the maximum output data rate is not only a function of T
INTERVAL
 but equals 
1/(T
CONV_BURSTWOC
 + T
INTERVAL
). 
(3)  Conversion time table as a function of OSR and DIG_FILT. The cells in yellow are prohibited 
operating modes when HALL_CONF=0xC (default), but are allowed in case HALL_CONF=0x0. 
Typical T
CONV
(TXYZ) 
for OSR
2
=0x0 [ms] 
OSR 
0 
1 
2 
3 
DIG_FILT 
0 
1.27 
1.84 
3.00 
5.30 
1 
1.46 
2.23 
3.76 
6.84 
2 
1.84 
3.00 
5.30 
9.91 
3 
2.61 
4.53 
8.37 
16.05 
4 
4.15 
7.60 
14.52 
28.34 
5 
7.22 
13.75 
26.80 
52.92 
6 
13.36 
26.04 
51.38 
102.07 
7 
25.65 
50.61 
100.53 
200.37 
Table 1: Tconv as a function of OSR & DIG_FILT (scales w/ main oscillator variations) 
3901090393    Data Sheet 
Rev002  Page 4    Feb-2015 