Data Sheet
MLX90393 
Micropower Triaxis® Magnetometer Datasheet 
Figure 2: XY axis RMS noise versus conversion time, expressed in mGauss for GAIN_SEL = 0x7 
Figure 3: Z axis RMS noise versus conversion time, expressed in mGauss for GAIN_SEL = 0x7 
0
10
20
30
40
50
60
1 10 100
Noise Stdev [mGauss]
Conversion Time [ms]
XY-axis Noise over Conversion Time (bundled per OSR setting)
OSR = 0
OSR = 1
OSR = 2
OSR = 3
0
10
20
30
40
50
60
70
80
90
1
10
100
Noise Stdev [mGauss]
Conversion Time [ms]
Z-axis Noise over Conversion Time (bundled per OSR setting)
OSR = 0
OSR = 1
OSR = 2
OSR = 3
3901090393    Data Sheet 