Data Sheet
October 2017  BNO080 Datasheet  1000-3927 
www.hillcrestlabs.com  © 2017 Hillcrest Laboratories, Inc. All rights reserved.  10 / 57 
1.3.1 Pin Descriptions 
Figure 1-6 describes the function of each pin. 
Pin 
Number 
BNO080 Name 
Mode 
Description 
1 
RESV_NC 
NC 
Reserved. No connect. 
2 
GND 
Input 
Ground 
3 
VDD 
Input 
Supply voltage (sensors) (2.4V 
to 3.6V) 
4 
BOOTN 
Input 
Bootloader mode select 
5 
PS1 
Input 
Protocol Select pin 1 
6 
PS0/WAKE 
Input 
Protocol Select pin 0, also 
used to wake processor in SPI 
mode 
7 
RESV_NC 
Input 
Reserved. No connect. 
8 
RESV_NC 
NC 
Reserved. No connect. 
9 
CAP 
External capacitor (100nF to 
GND) 
10 
CLKSEL0 
Input 
Clock source selection. Internal 
pulldown. 
11 
NRST 
Input 
Active low reset 
12 
RESV_NC 
NC 
Reserved. No connect. 
13 
RESV_NC 
NC 
Reserved. No connect. 
14 
H_INTN 
Output 
Interrupt to host device 
15 
ENV_SCL 
Bidirectional 
Environmental sensor I
2
C clock 
16 
ENV_SDA 
Bidirectional 
Environmental sensor I
2
C data 
17 
SA0/H_MOSI 
Input 
Lower address bit of device 
address. In SPI mode, data 
input 
18 
H_CSN 
Input 
SPI chip select, active low 
19 
H_SCL/SCK/RX 
Bidirectional 
Host Interface I
2
C clock, SPI 
clock or UART RX 
20 
H_SDA/H_MISO/TX 
Bidirectional 
Host Interface I
2
C data, SPI 
data out or UART TX 
21 
RESV_NC 
NC 
Reserved. No connect. 
22 
RESV_NC 
NC 
Reserved. No connect. 
23 
RESV_NC 
NC 
Reserved. No connect. 
24 
RESV_NC 
NC 
Reserved. No connect. 
25 
GND 
Input 
Ground 
26 
XOUT32/CLKSEL1 
Output 
32K crystal output / clock 
source selection. Internal 
pulldown. 
27 
XIN32 
Input 
32K crystal input. / external 
clock 
28 
VDDIO 
Input 
Supply voltage (core and I/O 
domain) (1.65V to 3.6V) 
Figure 1-6: BNO080 pin descriptions 
The BNO080 can operate from an internal oscillator, an external 32.768 kHz clock or an external 32.768 kHz 
crystal. If an external clock is used it must be connected to pin 27. Hillcrest recommends a tolerance of 50ppm. If 
a crystal is used it must be connected across pins 26 and 27. Hillcrest recommends using a crystal with tolerance 
50ppm with 22pF capacitor loading. 