Owner manual

INSTALLATION INSTRUCTIONS
LAREDO LLC LUMINAIRE
STEP-I MOUNTING PREPARATION
* Drill wall for the hardware appropriate for
* Using template (page 4) lay over junction box (A)
on the wall. Mark at (3) hole.
the type of wall. Use 1/4" diameter bolts (not provided).
* Pull the supply wires (B) from junction box (A).
STEP-II FIXTURE MOUNTING PREPARATION
* To open door (C), loosen (2) retaining screws (D).
* Loosen (4) screws (E) then gently lower reflector (F).
STEP-IV WIRING
POWER MUST BE OFF.
(WIRING MUST BE PERFORMED
BY A QUALIFIED ELECTRICIAN)
* Wire service leads to fixture power leads
according to local and National Elec. Codes.
* For direct wire connections, connect
wire back to J-box on the wall. Connect
black to black and white to neutral then
push connections back inside J-box (A).
* Apply caulking sealant around the
top and both sides of the housing.
* Tighten bolts securely.
* Hang fixture on the mounting hardware
at the wall thru key-slots opening (J).
* Insert all wires (B) thru opening
at the back of housing.
STEP-III FIXTURE MOUNTING
(Fig. 6)
ground wire to green wire then push
(Fig. 1)
Hubbell Lighting, Inc. Doc. Number: 93015030
A subsidiary of Hubbell Incorporated Revision: *
701 Millennium Blvd • Greenville, SC 29607
Phone: (864) 678-1000
FIG. 5
FIG. 3
(Fig. 6)
(Fig. 6)
(Fig. 8)
(Fig. 2)
(Fig. 4)
SEE PAGE 4
FULL SIZE
TEMPLATE
READ ALL INSTRUCTIONS CONTAINED HEREIN BEFORE PROCEEDING WITH INSTALLATION OF FIXTURE.
WARNINGS:
- HUBBELL LIGHTING WILL NOT WARRANTY ANY FIXTURES FOR ANY REASON IF THE INSTALLER OF THE
FIXTURE DOES NOT READ AND COMPLY WITH ALL OF THE INSTRUCTIONS CONTAINED HEREIN.
- DISCONNECT POWER BEFORE INSTALLATION OR SERVICING.
- INSTALL, OPERATE AND MAINTAIN TO MEET ALL APPLICABLE CODES.
- ALL SERVICING OR RELAMPING MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL.
- ALL CONNECTIONS SHOULD BE CAPPED WITH SUITABLE INSULATED WIRE CONNECTORS (BY OTHERS).
- LAMP AND BALLAST MUST BE EQUAL ANSI CODE AND WATTAGE.
- THIS LUMINAIRE IS APPROVE ONLY FOR WALL MOUNT AND DOWNWARD ORIENTATION IN WET LOCATION.
1.00 REF.
4.56 REF.
5.00 REF.
MARK AT
CENTER
ALIGN WITH TOP EDGE
OF JUNCTION BOX
FIG. 1
A
B
* For optional quick release door latch,
push pin to open door.
* Lossen screws (G), remove cover (H).
(Fig. 3)
(Fig. 5)
FIG. 4
FIG. 2
C
D
N
PUSH PIN
F
E
E
H
G
PAGE 1 OF 8
PAGE 1 DE 8
PAGINA 1 DE 8

Summary of content (8 pages)