Datasheet

60
www.spaun.com
SAT IF
SAT IF
Model
Art. No.
SUS 21 F
865104
EAN 4040326651049
Inputs 2
SATInputLevel 65 ... 95 dBμV
Tap loss
Terr5...862MHz
2 dB
SATOutputLevel 82 dBμV
Isolation
> 35 dB
Currentconsumptionmax.+LNB 130 mA
Ambient temperature -20 ... +50 °C
Dimensions (mm) 39 x 107 x 26
UNiSEqC Single Cable System 2 in 1x2 according to EN 50494
SUS 21 F
Another innovation is the SUS 21 F, which enables two
receivers or a dual tuner receiver (PVR) to be connec-
ted via a single coaxial connection. The device is simply
plugged onto a conventional multiswitch. For this, the SUS
21 F uses two subscriber outputs of the multiswitch or of
aQUADLNB,whichserveasitsinputsignals.Asingle
coaxial cable can then be led into the dwelling, and used
to supply either two separate receivers or a PVR (dual
tuner) receiver. The receivers used must however support
the single-cable protocol as per EN 50494. The SUS 21
F is supplied with power via the receiver, or via a mains
adapter where required (optionally available).
SAT IF:
• SCRmultiswitchforthedistributionofupto8
SAT IF signals and terrestrial.
• TheselectionoftheSATIFpositionisaffected
by the receiver through a specific DiSEqC
TM
command according to EN 50494
• Nolimitationontransponderreception
• Allsubscriberoutputsareautomaticgaincontrolled
• MultipurposeLEDstatusnotification
• F-inputforoptionalwallpowersupply
(SNG 18/1000, Art.Nr.: 832114)
• TheSUS21Fhasajackdistanceof20mmandcan
be therefore directly connected to almost every
SPAUN multiswitch/cascade.
Terrestrial:
• Theterrestrialsignal(FM,DVB-T,CATV)
is looped through
• Thereceptionoftheterrestrialsignalisalsopossible
when the SAT-receivers are switched off
LED signal indication:
Optional:
Universal AC Adapter
SNG 18/1000 (Art. No.: 832114)
SCR-Address Frequency
1 1076MHz
2 1178MHz
SCR frequencies:
Standby Function
Energy
Saver!
Meaning LED
Remote voltage 13 V green
Valid command being executed green flashing
Short circuit red
Remote voltage 5 .. 10 V red flashing
Remote voltage > 15 V orange
Band orange flashing