Installation Guide

INSTRUCTIONS FOR MODELS
NEED HELP?
92-CPT-1000-UNI-K-R2
For additional assistance or service please contact:
SPEAKMAN
®
Company
400 Anchor Mill Road
New Castle, DE 19720
800-537-2107
customerservice@speakman.com
www.speakman.com
CPT-1000-UNI
CPT-1300-UNI
Kohler Installation
TOOLS AND SUPPLIES
IMPORTANT
SAFETY TIPS
Cover your drain to prevent loss of parts. Be sure to
always wear proper eye protection.
MAINTENANCE
Your new Valve Trim is designed for years of
trouble-free performance. Keep it looking new by
cleaning it periodically with a soft cloth. Avoid
abrasive cleaners, steel wool, and harsh chemicals as
these will dull the finish and void your warranty.
WARRANTY
Additional warranty information can be found at:
www.speakman.com
Drill Drill Bit
Ø1/4” (0.25”)
Phillips
Screwdriver
Measuring
Tape
• Circular Trim Package shown for reference. While
the appearance of your trim may be different, the
installation steps are the same.
• This Trim Package is intended to mount only to the
following Kohler valves. Please verify the model of
your valve prior to installation.
K-304-CS-NA
K-304-CX-NA
K-304-PS-NA
K-304-PX-NA
K-304-US-NA
K-304-UX-NA
K-304-K-NA
K-304-KS-NA
Verify that existing Valve is installed correctly
per manufacturers instructions. If valve is not
installed correctly, installation of the Universal
Valve Trim may not be possible.
1
Using a Ø1/4” (ø.25”) Drill Bit, enlarge the 4 holes shown below in the existing Kohler
Mounting Flange.
2
Clean front surface of wall. Install Valve Mounting Plate (1) to existing Kohler Valve, using the
10-24 x 1-½” screws (2) provided. Take care to not over tighten mounting screws or damage may
occur.
NOTE: Valve Mounting Plate (1) should sit flush upon Kohler Mounting Flange (3) when secured.
3
Secure the Wall Mounting Plate (1) to the Valve Mounting Plate (2) using the 8-32 X 1-½” Screws
(3) provided.
NOTE: The back surface of the Valve Mounting Plate
Assembly (1) should sit flush against the wall when
installed correctly.