Installation Sheet

SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
11/23/15 www.speakman.com 92-S-8700-06
SPEAKMAN
®
S-8700-CA, S-8700-CA-E
Installation, Maintenance & Operation Instructions
SENSORFLO® BATTERY POWERED LOW SPOUT LAVATORY FAUCET
DESCRIPTION
Speakman SENSORFLO® faucet. Battery powered low spout lavatory sensor faucet. All metal spout
assembly consists of polished chrome plated removable cover and black powder coated chassis. Sensor
module powered by two (2) 3-volt DC lithium batteries with waterproof connectors housed above counter in
faucet body. Low battery warning light. Solenoid with built-in filter. Vandal resistant 60 second time out
feature. Water conserving vandal resistant recessed aerator reduces water flow to 1.5 GPM / 5.7 LPM to
meet requirements of ANSI A112.18.1M for flow rates. ADA compliant. Note: 3/8’ Stainless Steel Hoses are
optional.
Specifications
INLET SUPPLY: 3/8” COMPRESSION WITH MALE THREADS
FLOW RATE: 1.5 GPM / 5.7 LPM or 0.5 GPM / 1.9 LPM
SHIPPING WEIGHT: 4.1 LBS
Options:
BO
Vandal Resistant 0.5 GPM Flow
Control
LF
Vandal Resistant Laminar 1.5 GPM Flow Control
HS
3 Stainless Steel Hoses for use with
Tee or Mixer
T
Tee with check valves
HTS 1 Stainless Steel Flexible Hose
TMV
Under-Counter Thermostatic Mixing Valve with
check valves
GB
Vandal Resistant 1.5 GPM Aerator
Outlet Device
VRS
Vandal Resistant Screws with Wrench
E
Vandal Resistant 0.5 GPM Spray
Outlet
Installation
Remove cover from faucet body. Disconnect sensor module wires and remove module from faucet. Remove
battery cover from module and install new batteries, taking care to ensure correct polarity. Reassemble in
reverse order as above. Make sure module wire is plugged in and clipped into place on top of the module.
Wires should be on the inside of cover screw bosses of chassis to prevent pinching. Reattach cover to faucet
with screws and wrench provided. Install vandal resistant aerator with wrench provided. Ensure gasket is
properly seated on bottom of faucet chassis. Carefully feed wire from faucet through deck hole, mounting
faucet on fixture. Attach notched wire guard (notched end up) washer and lock nut onto faucet shank and
secure faucet to fixture. CAUTION: Sensor module wire must be inside channel of rubber wire guard to keep
wire from being pinched or cut when tightening washer and lock nut. Attach outlet of solenoid valve to
shank of faucet. Attach supply to solenoid valve using 3/8” compression fittings. DRY CONNECTIONS
ONLY. Connect wire from faucet to solenoid valve. With drain installed, turn on water and activate the
faucet, checking for proper operation and all connections for leaks.

Summary of content (3 pages)