Installation Guide

SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
7/28/15 www.speakman.com 92-S-8700-R5
SPEAKMAN
®
S-8800, S-8800-CA, S-8800-CA-E
Installation, Maintenance & Operation Instructions
SENSORFLO® AC/ELECTRIC POWERED LOW SPOUT LAVATORY FAUCET
DESCRIPTION
Speakman SENSORFLO faucet. AC/Electric powered low spout lavatory sensor faucet. All metal spout
assembly, consists of polished chrome plated removable cover and black powder coated chassis.
Sensor/electronics module housed above counter in the faucet body. Sensor module powered by 120 Volt
AC transformer. Solenoid with built-in filter. Vandal resistant 60 second time out feature. Water conserving
vandal resistant recessed aerator reduces water flow to 1.5 GPM/5.7 LPM (MAX) to meet requirements of
ANSI A112.18.1M for flow rates. ADA compliant. Note: 3/8” compression stainless steel hoses are optional.
Specifications
TRANSFORMER: 120 VOLT AC
INLET SUPPLY: 3/8” COMPRESSION WITH MALE THREADS
FLOW RATE: 1.5 GPM/5.7 LPM (MAX)
SHIPPING WEIGHT: 4.7 LBS
Options:
BO
Vandal Resistant 0.5 GPM Flow
Control
LF
Vandal Resistant Laminar 1.5 GPM Flow Control
HS
3 Stainless Steel Hoses for use with
Tee or Mixer
T
Tee with check valves
HTS 1 Stainless Steel Flexible Hose
TMV
Under-Counter Thermostatic Mixing Valve with
check valves
GB
Vandal Resistant 1.5 GPM Aerator
Outlet Device
VRS
Vandal Resistant Screws with Wrench
ELF
Vandal Resistant Laminar 1.2 GPM
Flow Control
Installation
Install vandal resistant aerator with wrench provided. Ensure gasket is properly seated on bottom of faucet
chassis. Carefully feed wires from faucet through deck hole, mounting faucet on fixture. Attach notched wire
guard (notched end up) washer and lock nut onto faucet shank and secure faucet to fixture. CAUTION:
Sensor module wire must be inside channel of rubber wire guard to keep wire from being pinched or cut
when tightening washer and lock nut. Attach outlet of solenoid valve to shank of faucet. Attach supply to
solenoid valve using 3/8” compression fittings. DRY CONNECTIONS ONLY. Plug AC transformer unit into
120 VAC outlet and connect wire with black plug on faucet to plug on the transformer. Connect yellow wire
from faucet to same colored wire on solenoid valve. With drain installed, turn on water and activate the
faucet, checking for proper operation and all connections for leaks.
OPERATION
Speakman SENSORFLO faucets are thoughtfully designed for all in mind. Require no handles to turn, lift or
push, water flows only when hands are in the lavatory basin. Built in vandal resistant circuitry shuts off the
water after continuous flow of approximately 60 seconds. This feature prevents flooding; water is easily
turned on again by placing one’s hands under the lavatory spout.

Summary of content (2 pages)