Installation Guide

SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
09/26/17 www.speakman.com 92-SC-1210-1220-05
SPEAKMAN
®
SC-1210-AF, SC-1220-AF
Installation, Operation & Maintenance Instructions
COMMANDER EXPOSED SHOWER
DESCRIPTION
Speakman Commander exposed shower on 6” centers. 1/4 turn ceramic cartridges covered by 25-year
warranty. Chrome plated patented vandal-resistant four arm handles with color-coded indexes. Reversible
valve bodies. S-2272-E2 Shower head rated at 2.0 GPM / 7.6 LPM maximum to meet existing ASME
A112.18.1/CSA B125.1 standard. Polished chrome plated brass body, gooseneck with support strap, and supply
pipes (SC-1210-AF only). Rough chrome plated brass body and galvanized gooseneck with support strap
(SC-1220-AF).
SPECIFICATIONS
SUPPLY: 1/2 NPT MALE (SC-1210-AF), 1/2 NPT FEMALE (SC-1220-AF)
FLOW RATE: 2.0 GPM / 7.6 LPM MAX
SHIPPING WEIGHT: SC-1210-AF: 12.2 LBS, SC-1220-AF: 5.5 LBS
Options:
LH
Less Shower Head
LSP
Less Supply Pipe (SC-1210-AF only)
S-2252
Shower Head
S-2251
Shower Head
S-2292
Shower Head
S-2253
Shower Head
INSTALLATION
NOTE- Shut off water supplies. Supplies must be on 6” centers. Recommended height from center of valve
body to floor is 54”. Valve body is reversible to take supplies from below.
1) FITTING WITH WALL FLANGE: Apply pipe sealant to one end of supply pipes (provided). Screw pipes into
supply lines.
NOTE- Supply lines must have 1/2 NPT female threaded ends and be 1-1/8” from center of supply line to
finished wall.
FITTING WITH LUGS: Supply lines must have 1/2 NPT male threaded ends and be 7/8” from center
of supply line to finished wall.
2) Apply sealant to threads of supply lines. Slip coupling nuts onto lines and screw swivels up hand tight.
Gripping on small diameter of swivels with a pipe wrench, tighten pipes and/or swivels.
3) Slip strap onto gooseneck. Apply sealant to inlet threads of gooseneck and screw into valve body. Tighten
and position outlet with valve body.
4) Placing rubber washers on inlets of valve body, position body assembly up to swivels and tighten coupling
nuts. Hold assembly up against wall and mark location of mounting holes for valve body and gooseneck
strap. NOTE: Gooseneck strap location optional. Disconnect assembly from supply lines.
5) Drill starter holes for mounting screws.
NOTE: Wall must be supported where body and strap mounts.
6) Connect valve assembly to supply lines and tighten coupling nuts with wrench. Fasten body and strap to
wall using (4) wood screws provided.
7) Turn water supplies on and flush both hot and cold sides of fitting.
8) Apply sealant to threads of gooseneck. Screw shower head onto gooseneck and tighten with pipe wrench.
Check all connections for leaks.

Summary of content (2 pages)