Installation Guide

INSTRUCTIONS FOR MODELS
92-SFC-9790-01
For additional assistance or service please contact:
SPEAKMAN
®
800-537-2107
customerservice@speakman.com
www.speakman.com
SFC-9790
TOOLS AND SUPPLIES
Adjustable
Wrench
Extended Phillips
Screwdriver
Pencil Scissors
Aerator
Wrench
(included)
HELPFUL TOOLS & SUPPLIES:
Safety
Glasses
Liquid
Soap
Foam
Soap
Warranty information can be found at:
www.speakman.com
WARRANTY
MAINTENANCE
Cover your drain to prevent loss of parts. Be sure to
wear eye protection while cutting pipe.
SAFETY TIPS
IMPORTANT
• Be sure to read instructions thoroughly before
beginning installation.
• Do not over-tighten any connections or damage
may occur.
• This faucet has an operating range of 20-80 psi.
Your new Speakman Product is designed for years of
trouble-free performance. Keep it looking new by
cleaning it periodically with a soft cloth. The use of harsh
chemicals and abrasives may damage the finish and
void the product warranty. Please be sure to only use
approved cleaners. Please contact Speakman for any
clarification of acceptable cleaners.
1
Place all hoses, sensor wires and threaded shanks through the mounting holes
one at a time. Take extra precautions to avoid pinching any wires. Lower Faucet
and Sensor Soap Dispenser assembly into position.
FAUCET AND SOAP DISPENSER MOUNTING
2
From beneath, install Rubber Wire Guard (1) over the Shank and pass the
Sensor Wires through the Notch to prevent pinching of wires. The Notch should
be facing right. Install Metal Washer (2) and Mounting Nut (3) onto Shank.
Wrench tighten Mounting Nut (3). Verify that Sensor Wire is not pinched.
FAUCET MOUNTING
3
From beneath, install the Rubber Washer (1), Metal Washer (2) and Mounting Nut (3) to secure the Sensor
Soap Dispenser. Wrench tighten Mounting Nut (3). Verify that the wires and hoses are not pinched.
SOAP DISPENSER MOUNTING
4
5
Thread the Solenoid Outlet (2) directly onto
The Shank (1) by hand. Verify that the Rubber
Washer (3) is fully seated inside the swivel nut.
Wrench tighten the connection.
DRY CONNECTION ONLY.
DO NOT USE ANY SEALANT
ON THIS CONNECTION
5
6
Assemble "INLET" Supply Hose (1) (not supplied),
to the "INLET" connection (2) of Solenoid.
Wrench tighten.
DRY CONNECTION ONLY.
DO NOT USE ANY SEALANT
ON THIS CONNECTION
FAUCET SOLENOID BOX INSTALLATION
6
Make electrical connections from the Sensor Eye to the Solenoid Assembly. Connect the Blue Male Ended Wire
to the Blue Female Connection. Connect the Green Male Ended Wire to the Green Female Connection. To
further aid proper alignment, there are white alignment lines on the connector ends. These alignment lines
should face forward when properly installed.
GREEN
BLUE
FAUCET SENSOR CONNECTIONS
7
Place the Control Box (1) against the desired mounting surface while ensuring adequate clearance for servicing
of all connections. If using the A/C Adapter, consider the distance to the nearest electrical outlet. Control Box
should be mounted so the Soap and Air Outlet Ports are facing up.
A/C ADAPTER
SOAP DISPENSER CONTROL BOX MOUNTING

Summary of content (6 pages)