Installation

Page 12 of 15
SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
1/15/16 www.speakman.com 92-S-9100-9200-05
HOSE INSTALLATION BETWEEN MO (MANUAL OVERRIDE) AND ACM (ABOVE COUNTER MIXER) OR
UCM (UNDER COUNTER MIXER
For ease of installation attach hoses to ACM (above counter mixer) and MO (manual override) diverter
before installing under the sink.
1. Attach hot supply hose 1 to inlet ports of mixer (H port) 1 either ACM or UCM.
2. Attach cold supply hose 2 to inlet ports of mixer (C port) 2 either ACM or UCM.
3. Connect one end of diverter supply hose 3 to the Elbow outlet 3 on ACM or TEE outlet 3 on UCM.
Connect opposite end of hose 3 to the inlet port 3 of the MO Diverter valve.
4. Connect one end of the diverter discharge hose 4 to the outlet port 4 on the MO diverter valve.
Connect opposite end of hose 4 to by-pass port 4 of the Solenoid valve.
5. Connect one end of Solenoid supply hose 5 to the outlet port 5 on ACM or TEE outlet 5 on UCM.
Connect opposite end of hose 5 to the inlet port 5 of the Solenoid valve
.
MANUAL OVERRIDE
(MO)
ABOVE COUNTER MIXER
(ACM)
UNDER COUNTER MIXER
(UCM)