Installation

Page 14 of 15
SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
1/15/16 www.speakman.com 92-S-9100-9200-05
TROUBLESHOOTING
Before calling Speakman Company for service, please run through the following checklist of troubleshooting
steps.
IF WATER FLOW FROM THE FAUCET DECREASES:
1. Make sure the supply stops are open.
2. Ensure both the hot and cold water Temperature Adjusters are not in the closed position (to open, screw
out the hot and cold water Temperature Adjusters (counter-clockwise direction)
3. Check that the In-line Filter in the Solenoid body is not blocked with debris. Remove slotted filter screw
from the Solenoid Body and rinse filter screen with clean water. Reassemble the filters, open stops, and
check water flow. Stops must be off when filters are removed.
4. Remove the Aerator from the spout using the outlet wrench. Operate the faucet with outlet device
removed. If water flow is acceptable, disassemble the outlet device and rinse components with clean
water.
5. If 1), 2), 3), or 4) do not resolve the problem; call Speakman Company Customer Service for assistance.
IF NO WATER FLOWS FROM THE FAUCET:
If you can hear clicking sound of solenoid opening, but no water flows
1. Check to see that the hot and cold water wall stops are completely open.
2. Check that the Yellow connector is connected to Solenoid, the Red to Power Module and Black to
transformer.
3. Activation light blinks continuously, even when faucet is not in use. This continuous blinking of the
activation light indicates that the batteries inside of the sensor module have low voltages and need to be
replaced.
4. Check to see that the In-Line Filter in the Solenoid is not blocked by debris (if it is, clean it).
If you do not hear a clicking sound from the solenoid and water does not flow
Disconnect the existing Sensor Module and connect a new module directly with Red and Yellow to the
Solenoid. Activate the new sensor module and check for water flow. If the water flows, disconnect the new
module and reconnect the old module and activate. If the old Sensor module still does not work, should be
replaced.
If Batteries have been replaced but Faucet still fails to operate
1. Check battery polarity and electrical connection. Make sure wire plugs are fully inserted into sockets.
2. If faucet does not operate, replace existing sensor module with one you know to be functioning.
3. If faucet operates, contact Speakman Company at 800-537-2107 for a replacement sensor module.
4. If faucet still does not operate, call Speakman Company at 800-537-2107 and ask for the Solenoid Repair
Kit, Part No. RPG76-0039, to be shipped to you. Once the kit is received, shut off the hot and cold water
supplies to the faucet. Remove sensor module bracket and sensor module. Next, remove the four (4)
screws that hold the coil plastic case to the solenoid body and follow the instructions supplied with the
kit. After replacing all parts supplied in the kit, reassemble the faucet, open stops, and test the faucet.
If the faucet activates but the water will not shut-off
Hold a hand in front of Sensor at about 6”-8” for more than 2min until the water flow stops. Once the water
stops, remove your hand and wait 10sec. Then place your hand in front of Sensor and it should operate
properly.
If the Faucet still does not shut-off, cover the front of the sink with a towel. This will eliminate potential of
reflections activating the Sensor.
If it is a new installation and still it is not working, change the Solenoid.
If it was used for a while and now is not working, rebuild it with the Repair Kit RPG76-0039.