Installation

Page 4 of 15
SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
1/15/16 www.speakman.com 92-S-9100-9200-05
Under sink, place rubber wire guard (with notch facing
forward) and pass the wires through notch. The wires
should be inside the channel of the rubber wire guard
to prevent pinching when tightening. Insert metal
washer and tighten the locknut to provide tension into
the rubber guard. While tightening make sure the
position of Faucet on top of counter is straight. Verify
that no connector wires are pinched.
Install the solenoid by engaging the thread by hand
first and continuing to tighten with an adjustable
wrench (you will need to hold Faucet
on top to prevent
rotation). Do not overtighten and don’t use any sealant.
DRY CONNECTION ONLY.
Connect the two faucet wires with the solenoid wires.
The connectors are color coded. If you have an AC/DC
unit, there is an additional wire with black connector
coming from the top of power module that needs to be
connected to the transformer provided.
(not shown)
NOTE: It is important to make yellow connection
first, followed by the red connection.
If the option has an UCM (under counter mixer),
connect it to the inlet of the solenoid: Start thread by
hand and then tighten using an adjustable wrench (do
not overtighten). DRY CONNECTION ONLY.