Installation
SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
06/12/17 speakman.com 92-SE-236-PR-02
SE-236-PR ROUGH-IN
MAINTENANCE
Should you need parts to repair this unit,
please reference the parts listing below for
correct part numbers. Reference additional
technical sheet (supplied) for information on
the SE-911-PR stay-open valve. Before any
maintenance is done be sure to shut the
water supply off.
WARNING: Use only genuine Speakman
parts when repairing or replacing
components.
To order parts call 1-800-537-2107.
REPLACEMENT/REPAIR PARTS
ITEM PART/GROUP # DESCRIPTION
1 SE-911-PR 1” Stay-Open Valve With Pull Rod
2 SE-830 10” Stainless Steel Shower Head
3 26-0250-RCP Ceiling Pipe Flange
4 G04-0722 Short Lever Handle w/Plunger
5 RPG47-0046 Aluminum Pull Rod
FLOW DATA
SHOWER:
NOTE: This unit should be connected to an uninterrupted source
of potable water, with a minimum flowing pressure of 20 PSI and
a maximum static pressure of 80 PSI.
FLOW PRESSURE PSI (BAR) 20 (1.38) 60 (4.14)
FLOW RATE GPM (LPM) 20 (75) 25 (94)
Note: All units meet existing
ANSI Z358.1 Standards and
OSHA Rules. Product
improvements may cause
specification and dimensional
changes without notice.