Step 1: Valve Body Mounting - The valve bodies are marked
with red marker for the hot supply and blue marker for
the cold supply.
a. Screw locknuts down onto the valve body assemblies.
b. Place the cup washers onto valve bodies.
c. Working from below the sink, insert the valve body
assemblies through holes in sink or countertop. From above
sink, place rubber washers onto the valve bodies.
d. Next, screw flange nuts onto valve bodies with flat side up,
flush with top of valve bodies and tighten flange nut using
the set-screw.
e. From under sink, screw locknuts up hand tight. Position
bodies so that outlets are accessible and wrench tighten
locknuts while holding bodies in place.
Step 2: Gooseneck Eyewash Mounting –
a. Slip the base washer onto the gooseneck eyewash
and slip through the center hole of the sink or countertop.
b. The gooseneck eyewash swivels through 200° of
rotation. Position the base of the gooseneck eyewash so
the setscrew hole in the base is pointing towards the back
of the sink or countertop.
Note - For rigid gooseneck, position the gooseneck and
tighten the setscrew in the mounting base. From below
the sink slip the cup washer onto the shank and use the
nut to tighten the assembly down onto the sink or
countertop. Important- Lubricate gooseneck eyewash
shank lower O-ring.
c. Important- Next insert the rubber seal into the adapter
and screw the adapter onto the shank of the gooseneck
eyewash until it bottoms out (Tape may be applied to
the shank). If the adapter needs to be positioned for hose
attachment, it can be backed off up to a maximum
of 1 / 2 turn.
Step 3: Hose Connections -
a. Screw valve body hoses onto the side outlets
of the valve bodies and tighten. Screw the other
end of the hoses onto base adapter.
b. Connect the vertical inlet of the tee to the cold
water inlet supply.
c. Connect the hot & cold water supply lines
to the inlets of the valve bodies and tighten
the coupling nuts.